INGEDRIVE LV800 |
General data |
Inverter type |
Two-level voltage source inverter with LV-IGBT power semiconductors |
Rectifier type |
Diode Front End (DFE) 12P, 18P, 24P
|
Active Front End (AFE) |
Main supply voltage range |
2x490 - 2x732 VAC |
480 - 690 VAC |
Output power range (1) |
1495 kW - 8620 kW
|
1055kW - 9090 kW |
Supply voltage tolerance |
Tipically ± 10% |
Supply frequency |
50 / 60 Hz (± 5 %) |
Input power factor |
0.91 - 0.96 for DFE rectifiers
1 for AFE rectifiers |
Output voltage |
0 to 440/660 VAAC
|
0 to supply voltage |
Output frequency |
0 to 120 Hz (higher on request) |
Efficiency at rated load |
Tipically > 0.97 for DFE rectifiers
Tipically > 0.96 for AFE rectifiers |
Motor types |
Induction, synchronous or permanent magnet motor |
Converter cooling |
Water cooled with built-in water to water heat exchanger |
Control properties |
Control types |
VC Vector Control / VF Voltage Frequency (2) |
Static speed acc. (closed loop) (3) |
<0.01% in field weakening / <0.01% at constant flow |
Static torque acc. (closed loop) (3) |
<1 % in field weakening / <1 % at constant flow |
Static torque acc. (open lloop) (3) |
<2 % in field weakening / <2 % at constant flow (for synchronous motors)
5 % in field weakening / <3 % at constant flow (for induction motors) |
Torque response time |
< 10 ms |
Shaft torque ripple (3) |
± 1 % |
Drive protection functions |
Overcurrent, overvoltage and undervoltage monitoring; earth fault; short circuit detection and protection; semiconductor failure monitoring; cooling supervision; phase loss and others |
Motor protection functions |
Overload (4), Overspeed |
Environmental Conditions |
Ambient temp. for storage |
- 20 ºC to + 55 ºC (for empty cooling system in water cooled version) |
Ambient temp. for transport |
- 25 ºC to + 55 ºC (for empty cooling system in water cooled version) |
Operation altitude |
< 2000 m above sea level (100 % load capacity)
> 2000 m above sea level (with derating) |
Relative air humidity |
5 % - 95 % (condensation not permitted) |
Paint colour |
RAL 7035 (others on request) |
Compliance with standards |
IEC 61800-2, IEC 60146-1-1, marine standars |
Water cooled converter |
Noise |
<75 dB (A) at a distance of 1m from the cubicle |
Ambient temp. for operation |
+ 0 ºC to + 45 ºC (higher with derating) |
Degree of protection |
IP44 (others on request) |
Primary circuit coolants allowed |
Seawater or freshwater |
Primary coolant temp. allowed |
+ 0 ºC to + 38 ºC (higher with derating) |
Primary circuit pressure drop |
< 1 bar |
Max. primary service pressure |
6 bar |
Max. primary ΔT |
5º C |
Secondary circuit coolant |
Controlled pre-mixed liquid (fresh water < 10 µS/cm + anti-freezing) |
Secondary circuit features |
Redundant pump |
Main Options |
Dynamic braking chopper, different communication modules, dv/dt filter, sinusoidal filter, input / output isolation switch, marine customization and others |