Smart remote terminal units | INGEPAC™ DA AU

INGEPAC™ DA AU devices carry out, in a single device, all the automation, measurement and supervision requirements related to a RMU:

  • Directional phase fault detection
  • Fault isolation automatic operations and load transfer
  • Protection
  • V, I, P and Q measurement of all the positions
  • Local and remote control of switchgear
  • RTU
  • Web server

 

Functions

  • Comprehensive position signaling
  • Complete measurement at the point of installation in the grid: V, I, P, Q, F, cos ϕ, active, reactive energy
  • Voltage measurement using reactive sensors
  • Directional fault passage detection
  • Automatic fault clearance
  • SCADA communication and remote equipment management using software tools or web access
  • Event recording: incidents, faults, oscillography
  • Measurement values log
  • Supply quality values and logs: harmonics, dips, surges, interruptions, etc.
  • IEC 61131-1 logics
  • Communication protocols: DNP3, IEC 103, IEC 61850...

 

Applications

  • Supervision of compact transformer substations (RMU)
  • Centralised control and automation of medium voltage switchgear

The development of communication networks in distribution grids, within the framework of evolving Smart grids, makes it possible to possess a significant amount of information on an entire electrical grid, for the purpose of manual or automatic operation or for making decisions in terms of maintenance and grid development.

INGEPAC DA AU, coupled with voltage sensors, is an affordable solution offering complete measurement and detection of fault bypasses anywhere in the grid. The same device provides communication to the SCADA (RTU) system, remote parameterising using software tools and web access for monitoring and configuration.

Besides supervision functional features, INGEPAC DA AU offers signalling for operating devices and allows the facility to control them remotely and/or automatically.

Benefits:

  • Faster fault identification and location
  • Reduction in customer hour loss
  • Improvement of availability and safety
  • Faster restoration of supply and reduction of outage time

Example of fault detection and isolation in automated transformer substations:

Fault passage isolation

  • 26/11/2024

    EV London Show

    In its fourth year, London EV Show will present a 18,000 Sqm dynamic exhibition floor featuring test drives and hands-on product demonstrations from 3...
  • 08/12/2024

    Idra World Congress

    The world needs clean water now. The compounding factors of population growth, escalating industrial water requirements, and the ominous specter of ri...
  • 11/12/2024

    Energaïa

    The EnerGaïa Forum, supported by the Occitanie Region offers leading environmental solutions for territories, cities and industries committe...

Sie benötigen weitere Informationen?

I agree to receive commercial communications from Ingeteam
I have read and I agree to Ingeteam´s privacy terms.
* You have to accept the Ingeteam´s privacy terms.
Smart Grids - Social media

Newsletter: Subscribe

LinkedIn: View page

 

Smart Grids - Contact

E-mail: marketing.pga@ingeteam.com

Phone: (+34) 944 039 600

Address: Ingeteam Power Technology, S. A. - Parque Tecnológico de Bizkaia, Edificio 110 - Zamudio, 48170, Spain